Ford 351-400M rod bolts
Applications
Ford - Small Block - Cleveland 351M
Ford - Small Block - Cleveland 400
Installation Instructions
Part Number: 154-6001 & 154-6021
Application: FORD 351-400M V8
Press Fit - Rod Bolt Installation
[1]
Please check the part-number(s) for your application
against the part-number(s) listed on the instruction sheet.
[2]
Make sure that there is an adequate chamfer around the
top of the connecting rod bolt hole to clear the radius
under the head of the bolt.
[3]
Press the bolts into the connecting rods and install the
rod caps.
[4]
Use ARP Ultra-Torque Fastener Assembly Lubricant
to lubricate the threads of the bolt and the nut face. Then
install the nuts onto the bolts and tighten them hand tight.
[5]
ARP recommends using the STRETCH METHOD when
tightening the bolts. Following the instructions for using a
stretch gauge, Stretch the bolts to . 0060 - . 0065 .
[6]
If you do not have a stretch gauge, torque the bolts to
50 ft-lbs (67.8 Nm) using ARP Ultra-Torque Fastener
Assembly Lubricant.
[7]
The connecting rods should always be re-sized after new
rod bolts are installed.
[8]
A log should be kept on the original non-torqued length of
each bolt. Bolts that have any permanent deformation or
have increased in non-torqued length by more than .001
in. should be replaced.
If you have any questions or need additional information please
contact us at (805) 339-2200 or by FAX (805) 650-0742
⚠ This is an automatically generated translation and unit conversion. Always refer to the original ARP instruction sheet for exact specifications. Errors may occur.
Heb je het artikel niet gevonden of heb je vragen? Neem gerust contact met ons op!
App ons direct via WhatsApp!
Stuur een berichtje naar 06‑30169408 en ontvang snel een persoonlijk antwoord.
WhatsApp is handig en snel, en je kunt eenvoudig foto’s of bestanden meesturen.
Geen wachttijd, gewoon direct contact.
We helpen je graag verder!